Modbus HMI

Modbus HMI software for Modbus TCP and Modbus RTU.

LinkView is HMI/SCADA software with Modbus TCP and Modbus RTU drivers built in. You design the screens in LinkView Studio in the browser, with nothing to install, and start with a 3-day trial. LinkView Runtime, included with the seat, runs them on the station.

Tags and connections

  • Define tags and reusable TypeDefs once, then connect them to Modbus TCP, or to Modbus RTU over serial.
  • Read coils, discrete inputs, input registers and holding registers, single register bits too, as bool, 16- or 32-bit integers, float32 or float64, in ABCD, CDAB, BADC or DCBA order.
  • A tag can name another unit id, from 0 to 255. Modbus RTU sets the serial port, baud rate, parity, data bits and stop bits.
  • One project can hold Modbus, OPC UA and MQTT connections side by side.
  • In the browser, Preview runs your screens against a built-in pump-station simulator and never contacts a device. A deployed Runtime is what talks to the PLC, and deploying needs a seat.

On the station

  • Alarms move through unacknowledged, acknowledged and returned-to-normal states, and operators can shelve one for a set time, with a reason.
  • Trends plot several pens from the built-in historian, which keeps tags in SQLite on the station, 365 days by default.
  • Critical tags ask for confirmation, and held buttons return to their safe value when released.
  • Sign-ins and writes go into a hash-chained audit trail.
  • Scripts run in QuickJS at startup, on an interval, when a tag changes, on a cron schedule, or from a screen element or an alarm.
LinkView Studio Design workspace with the HC-01 Pumps screen on the canvas: the P-102 pump card, an instance of the Pump card component, is selected, with its Duty variant and unit input in the inspector and the layers list on the left
STUDIO · DESIGN · WATER-BOOSTER · 1600×900

What it costs

Studio is €399.99 per seat per month or €3,999.99 per seat per year, in EUR. Runtime is €0 on any number of stations. The trial lasts 3 days and asks for no payment details.

Questions

Does LinkView support Modbus RTU over serial?

Yes. Modbus RTU over serial is built in, next to Modbus TCP, OPC UA and MQTT. You set the serial port, baud rate, parity, data bits and stop bits.

Which Modbus data types and byte orders are supported?

Bool, 16- and 32-bit integers, float32 and float64, from coils, discrete inputs, input registers and holding registers, in ABCD, CDAB, BADC or DCBA order.

Can I test Modbus screens without a PLC?

In the browser, Preview runs your screens against a built-in pump-station simulator and never contacts a device. A deployed Runtime is what talks to the PLC, and deploying needs a seat.

What does a Modbus HMI runtime cost?

LinkView Runtime is included with your Studio seat, on any number of stations. Studio runs in the browser at €399.99 per seat per month or €3,999.99 per seat per year, and the 3-day trial asks for no payment details.

Does Runtime need internet access?

No. Runtime runs a signed package on the station. It goes online only if you pair the station for remote publishing or let it check for updates.