OPC UA HMI
OPC UA HMI and SCADA software.
LinkView is HMI/SCADA software with an OPC UA driver built in. You design the screens in LinkView Studio in the browser, with nothing to install, and start with a 3-day trial. LinkView Runtime, included with the seat, runs them on the station.
Model once
- Define tags and reusable TypeDefs once, then connect them to OPC UA.
- Connect with security None, Sign or SignAndEncrypt, anonymously or with a user name and password. Tags are read through a subscription.
- On a secured connection the driver trusts the server certificate on first use and refuses a different one later.
- Connection passwords stay out of the project file; the project keeps only a reference.
- Turn a group into a component with variants, and give a screen layout variants for other panel sizes.
- Faceplate and PID faceplate widgets are built in.
On the station
- Alarms move through unacknowledged, acknowledged and returned-to-normal states, and operators can shelve one for a set time, with a reason.
- Trends plot several pens from the built-in historian, which keeps tags in SQLite on the station, 365 days by default.
- Critical tags ask for confirmation, and held buttons return to their safe value when released.
- Sign-ins and writes go into a hash-chained audit trail.
- Scripts run in QuickJS at startup, on an interval, when a tag changes, on a cron schedule, or from a screen element or an alarm.
- An alarm class can post each alarm event as JSON to a webhook and email it through the station's mail server.
- Reports run on a cron schedule, keep each run on the station as HTML or CSV, and can be emailed.

What it costs
Studio is €399.99 per seat per month or €3,999.99 per seat per year, in EUR. Runtime is €0 on any number of stations. The trial lasts 3 days and asks for no payment details.
Questions
Where is the OPC UA password stored?
Not in the project file. Connection passwords stay out of it, and the project keeps only a reference.
Which OPC UA security modes does LinkView support?
None, Sign and SignAndEncrypt, with Basic256Sha256, Aes128_Sha256_RsaOaep or Aes256_Sha256_RsaPss, anonymously or with a user name and password.
Can one project mix OPC UA and Modbus?
Yes. One project can hold OPC UA, Modbus and MQTT connections side by side.
What does a OPC UA HMI runtime cost?
LinkView Runtime is included with your Studio seat, on any number of stations. Studio runs in the browser at €399.99 per seat per month or €3,999.99 per seat per year, and the 3-day trial asks for no payment details.
Does Runtime need internet access?
No. Runtime runs a signed package on the station. It goes online only if you pair the station for remote publishing or let it check for updates.